Page History
...
Step | Action |
---|---|
1. Make sure to check 'Enable Admin Options' in 'Commands' menu. |
|
2. Select 'Load Pick List Definition – LexGrid XML' from 'Load' menu. |
|
3. A separate window will open to select a file to load. Select a file to load. |
|
4. Click 'Load' button. Status of load process will be displayed as the data is getting loaded. If everything goes well, you should see 'Errors Logged: false' and 'End State: completed' at the bottom of the status output. |
|
5. Pick List Definitions loaded should be displayed on the main console under 'Available Pick List Definitions'. |
|
...
Step | Action |
---|---|
1. Select Value Set Definition under 'Available Value Set Definitions' and click on 'Display Details' button (or double click on Value Set Definition). |
|
2. Separate window will be displayed with meta data of selected Value Set Definition at the top. |
|
3. Click on 'Definition Entries' tab to view Definition Entries of this Value Set Definition. |
|
4. Click on 'Properties' tab to view Properties of this Value Set Definition. And in this Properties view, you can select any particular property and click on 'Display Details' button to view more details like property qualifiers etc. of the selected property. !VSDDetails3.jpgClick on Properties tab.! |
|
5. Click on 'Supported Attributes' tab to view list of Supported Attributes of this Value Set Definition. |
|
...
Step | Action |
---|---|
1. Make sure to check 'Enable Admin Options' in 'Commands' menu. |
|
2. Select the Value Set Definition under 'Available Value Set Definitions' to be exported and click on 'Value Set Definition as LexGrid XML' under 'Export' menu. |
|
3. Enter the destination and the file name (should be .xml extension). Choose options appropriately and click on 'Export' button. 'Async Load' – Checking this will export the contents asynchronously'Fail on all errors' – Checking this will stop the export if any error occurs.'force' – Checking this will replace existing file. If there exists a file and this option was not checked, export will fail. |
|
4. Status of an export process will be displayed as the data is getting exported. If everything goes well, you should see 'Errors Logged: false' and 'End State: completed' at the bottom of the status output. |
|
5. Verify the exported file. 'valueSetDefinition' should be the top element and all its available contents (mappings, properties, definitionEntries etc) should be exported. |
|
Exporting Expanded Value Set (Value Set Resolution)
...
Step | Action |
---|---|
1. Click on 'Add' button within 'Coding Scheme References' group. !EditVSD6.jpgClick Add button|alt="Click Add button."! |
|
2. Enter the Coding Scheme Reference data in a separate window that opens. Make sure that you enter unique number for Rule Order. Rule Order: Mandatory field. The unique identifier of the definition entry within the definition as well as the relative order in which this entry should be applied.Operator: Mandatory field. How this entry is to be applied to the value set. Select appropriate value from the drop down list.Coding Scheme: Mandatory field. The local identifier of the coding scheme that the entity codes are drawn from. All available coding scheme local identifier will be available in the drop down list, you can choose from this list or enter different value if the coding scheme you want to reference is not yet loaded in the system. |
|
3. Click on 'ADD' button. | – |
4. Coding Scheme Reference added in previous step should now be visible within 'Coding Scheme References' group. |
|
5. Click 'Save' button to save the changes. |
|
...