NIH | National Cancer Institute | NCI Wiki  

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Select a Column Type, Datum or Condition. 

  2. Select a Column Name or select other and add a new one.

    Info
    titleColumn Notes
    You can add up to three cell viability Column Names, including cell viability, cell viability B, and cell viability C. You can further identify the column with the Column Value Type.
    1. For Column Type, Datum, the following characterization(s) display customized Column Name options.

      Characterization TypeColumn Type and Column Name Option(s)
      Physico-Chemical
      • MolecularMolecular Weight
      • Purity% purity for sample
      • RelaxivityR1, R2, T1, T2
      • SizePD1, Peak N , RMS size, Z Average
      • Surfacecharge, zeta potential
      In Vitro

      Enzyme Induction – % of Control

      In VivoClick Other to name the column yourself.
    2. For Column Type, Condition, all characterizations provide the Column Name options in the left column of the following table. The Column Name autopopulates the Condition Property options in the right column.

      Column Type, Condition Autopopulates Column NameColumn Name Autopopulates
      Condition Property

      Centrifugation

      N/A

      Culture Media

      media type, serum percentage

      Electromagnetic Radiation

      bandwidth, frequency, time, wavelength

      Freeze Thaw

      N/A

      Long Term Storage

      lyophilized, time

      Lyophilization

      time

      pH

      N/A

      Sample concentration

      N/A

      Short Term Storage

      lyophilized, time

      Solvent Media

      ion concentration, ionic strength, molecular formula, osmolality, serum percentage, with serum

      Sonication

      number of pulses, pulse duration

      Temperature

      N/A

  3. To further identify a column, select a Column Value Type.

    Info
    Once the column information is saved, the Column Type is shown in parentheses after the Column Name, such as cell viability (mean).


  4. Select a Column Value Unit, or select other and add one.
  5. If you want the same value to fill all rows in a column, add a Constant Value.

    Info
    titleFor Column Value Type, boolean
    For Column Value Type, boolean, enter a Constant Value of 1 for true and 0 for false.
  6. Click Save, and the column(s) are updated.

    Info

    If needed, click Set Column Order to change the order of the column headings in the matrix.


  7. Click Save in the Finding section.