The monthly NCI Imaging Informatics Webinar is organized by the Center for Biomedical Informatics and Information Technology (CBIIT) and the Cancer Imaging Program (CIP). It occurs on the first Monday of every month from 1:00 pm to 2:30 pm Eastern Time and features scientific presentations and project updates.
Join the Google Group for up-to-date information
Dial-In Information
Contact | Details |
---|---|
WebEx | https://cbiit.webex.com/cbiit/j.php?MTID=mdb5f537bde0cff01e5c7779f02680185 |
Meeting number (access code) | 732 377 553 |
Meeting password | tSX9U9c? |
Join by phone | 1-650-479-3207 Call-in toll number (US/Canada) |
Agenda of September 14, 2020 meeting
Topic |
---|
|
A key step in the pipeline of medical image analysis and computing algorithms is evaluating variations in the appearance of imaging data, especially in large multi-institutional cohorts such as TCIA. These image artifacts occur in the form of noise, motion, inhomogeneity, ringing, motion, and aliasing in radiographic scans. While these issues can impede diagnostic interpretation, they even more significantly affect the training of machine learning and computational analysis algorithms. Currently, the standard approach for assessing medical image quality is via manual inspection, a process that is both laborious as well as subjective. We have developed MRQy, an open-source tool to assess medical image quality and determine diagnostic/computational suitability both for individual datasets as well as cohorts; for MR images acquired of any body region. MRQy leverages a Python backend which employs a combination of modality-specific image features and quality measures (e.g. signal-to-noise ratio, coefficient of variation, contrast-to-noise ratio). These results can subsequently be interrogated in a specialized HTML5 based front-end, allowing for real-time filtering, visualization, and cohort creation. We will present the use of MRQy to evaluate multi-institutional cohorts in TCIA to identify the presence of specific image artifacts, as well as site- or equipment-specific variations (i.e. batch effects); which are essential to correct prior to further downstream analysis of radiographic images. |
|
Upcoming Calls
Date | Tentative Agenda |
---|---|
August 3, 2020 | Canceled |
September 14, 2020 |
|
October 5, 2020 |
|
November 2, 2020 |
|
December 7, 2020 |
|
Presentations and Recordings from Previous Calls
Presentations can be found at SlideShare
Date | Agenda | Recording |
---|---|---|
July 6, 2020 |
| MP4 file |
June 1, 2020 |
| MP4 file |
April 6, 2020 |
| MP4 file |
January 6, 2020 |
| MP4 file |
December 2, 2019 | Call was canceled due to RSNA | |
November 4, 2019 | Call was canceled due to conflicting meetings | |
October 7, 2019 |
| MP4 file |
September 9, 2019 |
| MP4 file |
August 5, 2019 |
| MP4 file |
July 1, 2019 | Joint Session with the CPTAC Special Interest Group
| MP4 file |