Panel | |||||||||
---|---|---|---|---|---|---|---|---|---|
| |||||||||
|
Topic: caIntegrator Usage
Release: release= caIntegrator 1.2
...
Date entered: August 31, 2010
...
topic=CaIntegrator Usage
Question
...
What is the format of caArray supplementary files that can be loaded into caIntegrator?
...
...
Answer
This knowledge base entry describes the format when creating supplemental files for use by caIntegrator. The supplemental files described here are to be added to an experiment in caArray prior to configuring a study in caIntegrator.
The file itself is a tab-delimited text file. The file extension can be anything, though .txt is typically used. The name of each supplemental file has to be unique within a caArray experiment.
Inside the file, each row in the file contains the data from one reporter. Each column in the file must have a unique header name. (i.e That is, you can not give two different columns the same column name.)
...
- SINGLE SAMPLE FORMAT
- MULTIPLE SAMPLE FORMAT
SINGLE SAMPLE FORMAT
The format requirements for the single sample format file are following:
- Minimum of two required columns.
- One column must contain the reporter/probe name.
- One column must contain the value be reported by the reporter.
- The file can have additional columns, though other than reporter/probe name and value mentioned above, the rest will be ignored.
- One SINGLE SAMPLE FORMAT file for each sample in the experiment.
An Refer to the illustration below for an example of SINGLE SAMPLE FORMAT can be found in the figure below:.
MULTIPLE SAMPLE FORMAT
The format requirements for the multiple sample format file are following:
- one column must contain the reporter/probe name.
- each additional columns are column contains the reporter values such that there is one column per sample.
- one MULTIPLE SAMPLE FORMAT file for the whole experiment.
- CAVEAT: Currently the MULTIPLE SAMPLE FORMAT is slower to load than the SINGLE SAMPLE FORMAT for platforms other than Agilent Copy Number. This performance issue is expected to be improved in a future release.
Scrollbar | ||
---|---|---|
|
...
Composition Setup |
---|
cloak.toggle.type = text
cloak.toggle.open=[show]
cloak.toggle.close=[hide]
|
Panel | |||||||||
---|---|---|---|---|---|---|---|---|---|
| |||||||||
|
Topic:
Date entered:
Question
Refer to the illustration below for an example of MULTIPLE SAMPLE FORMAT.
...
Have a comment?
Please leave your comment in the caIntegrator End User Forum.
...